Subclasses 1.1.1 to 1.3, the Code and the guarantee plan
What each licence allows
| Subclass | Work allowed (RBQ competency profile) |
|---|---|
| 1.1.1 New residential buildings covered by a guarantee plan, class I | Detached, semi-detached or row single-family house (co-owned or not) and multi-family building from duplex to quintuplex not held in divided co-ownership. |
| 1.1.2 Class II | Multi-family building held in divided co-ownership with at most 4 superimposed private portions (not counting parking and storage). |
| 1.2 Small buildings | Buildings covered by Part 9 of the National Building Code (as adopted by Chapter I of the Construction Code) not covered by 1.1.1 and 1.1.2; and 1.1.1 and 1.1.2 buildings only as a subcontractor for a holder of those licences. |
| 1.3 Buildings of all types | Any building, including those of 1.2. |
These four subclasses also allow some specialty work (subclasses 2.6, 3.1, 4.1, 5.1 and 6.1 of Schedule II) on a building covered by the licence.
The Construction Code, Chapter I
It adopts the National Building Code of Canada 2015 (NBC), amended by Québec. Division A: objectives and compliance; Division B: technical requirements; Division C: administrative provisions. Part 9 (housing and small buildings) covers buildings of at most 3 storeys in building height and at most 600 m² in building area, for residential, business, mercantile and medium- or low-hazard industrial occupancies. Other buildings fall under Part 3 and Part 4 (structural design by an engineer).
The guarantee plan for new residential buildings
A contractor building covered new residential buildings (1.1.1, 1.1.2) must join the mandatory guarantee plan (Regulation respecting the guarantee plan for new residential buildings, B-1.1, r. 8). That is why licence security is not required when only subclasses 1.1.1 and 1.1.2 are requested (B-1.1, r. 9, s. 26).
Québec amends the NBC
Examples of Québec amendments: all concrete must be produced by a plant holding a BNQ certificate of conformity; each storey of a dwelling unit must have glazing providing natural light of at least 5% of its floor area (s. 9.7.2.3 added by Québec); piping for a future sub-floor depressurization system (radon) is required under floors-on-ground of conditioned spaces (s. 9.13.4.3).